CS9911AS Programmable AC Hipot Tester

Recorder return

CS9911AS Programmable AC Hipot Tester

Series Model: CS9911AS、CS9911BS、CS9912AS、CS9912BS、CS9913AS、CS9913BS、CS9914AS、CS9914BS

Summary



·AC/DC withstanding voltage function

·Innovative Security Protection System
·Using DDS Principle to generate the accurate, stable, pure and less distortion sine waveform
·The rise and decline time of high voltage can be adjustable. It can meet the different requirements of different users
·Arc detection with two options modes of the current mode and the level mode
·Test results can be saved simultaneously and it support more complete statistical analysis operations

·Comprehensive testing with double frequency, range from 50Hz and 60Hz
·With open-circuit and short-circuit detection
·User-friendly interface, users can input data using front keys directly or using dial input. The operation ismore simple and accurate.
·Complete help tips of operation, effectively improve the efficiency of work.
·With TNT color LCD display, the measurement results is much clearer and more informative
·Test step, the system state information display synchronized. Users are easy to understand the testprocedure in testing for more information and system status

·Support the input of Character file names, whose maximum length can be up to 12 characters
·Supporting new, delete, jump and other shortcuts of documents and test step. It is facilitate for users to manage the test files.

·Supporting system log, recording the boot time, the total running time, the number of tests and other parameters of this instruments, It is facilitate for users to understand the information of instruments.
·Chinese and English bilingual interface to adapt to the needs of different users
·Support mass storage, can support file organization format for 50
* 40, 25*80,10* 200,5 * 400. ·It is suitable for different application requirements ofthe test

·The minimum resolution of ACW is 0.1uA, 0.1V; the minimum resolution of DCW is 0.01uA, 0.1V, the minimum resolution of insulation resistance test 0.001Mohm, 0.1V
·Support RS232/RS485/PLC/GPIB/USB / Ethernet, printer interface and other communication interfaces